Facility

Materials Preparation and Measurement Laboratory

The University of Chicago

Provides facilities for preparing, fabricating, processing and characterizing many types of samples, with scanning probe, electron, optical and thermal characterization instruments.

Official website External access available
From the facility’s official website · Checked Nov 19, 2026

Hubrief prepared this page from public sources. It doesn't mean the organization has joined or endorsed Hubrief.

Capabilities

  • Atomic force microscopy

    Scanning probe microscopes including AFM and STM.

    As the source puts it: “scanning probe microscopes (AFM and STM)”

  • Scanning electron microscopy

    Scanning electron microscopes.

    As the source puts it: “scanning electron microscopes (SEM)”

  • 3D printing

    Additive fabrication

  • Raman spectroscopy

    Raman characterization.

    As the source puts it: “Raman”

  • Fluorescence spectroscopy

    Steady-state and time-resolved fluorescence characterization.

    As the source puts it: “steady-state and time-resolved fluorescence”

Instruments & Tools (27)

Computing 1

  • COMSOL MultiphysicsMultiphysics simulation software

    Resources: Midway2 and Midway3 clusters

    Techniques Multiphysics simulation

    Instrument page

Electron microscopy 3

  • GeminiSEM 560Field emission scanning electron microscope · Zeiss GeminiSEM 560

    Modes: NanoVP and VP modes · Detectors: InLens SE, EsB, ETSE, C2D, aBSD

    Techniques Energy-dispersive X-ray spectroscopy · Scanning electron microscopy

    Instrument page
  • JCM-7000 NeoScopeBenchtop scanning electron microscope · JEOL JCM-7000

    Modes: High Vac, Low Vac, and Charge Reduction Modes; Live EDS and 3D modes · Detectors: SE and BSE detectors

    Techniques Energy-dispersive X-ray spectroscopy · Scanning electron microscopy

    Instrument page
  • MerlinField emission scanning electron microscope · Zeiss Merlin

    Probe: Probe continuously adjustable from 10pA to 40nA · Detectors: In-Lens SE, EsB, AsB, SE2

    Techniques Energy-dispersive X-ray spectroscopy · Scanning electron microscopy

    Instrument page

Etching 2

  • Plasma Etch PE-100Plasma etching and cleaning system

    Materials: Ar, O 2 · Sample size: 10" x 10" sample area

    Techniques Reactive ion etching

    Instrument page
  • Southbay RIE2000Reactive ion etcher

    Gases: He, CF 4 , O 2 , and SF 6

    Techniques Reactive ion etching

    Instrument page

Fabrication 9

  • Formlabs Form3 3D PrinterResin 3D printer

    Techniques Stereolithography

    Instrument page
  • Formlabs Form4 3D PrinterResin 3D printer

    Techniques Stereolithography

    Instrument page
  • Formlabs Form4B 3D PrinterResin 3D printer

    Techniques Stereolithography

    Instrument page
  • J850 Polyjet 3D PrinterPolyjet 3D printer · Stratasys J850

    Techniques Polyjet 3D printing

    Instrument page
  • ProtoMAX Waterjet CutterWaterjet cutter

    Techniques Waterjet cutting

    Instrument page
  • Ultimaker S5 3D PrinterFDM 3D printer

    Materials: PLA, PVA (support) · Processes: Build volume: 300 x 240 x 300mm

    Techniques Fused deposition modeling

    Instrument page
  • Ultimaker S8 Pro 3D PrinterFDM 3D printer

    Materials: PLA, PVA (support) · Processes: Build volume: 330 x 240 x300 mm

    Techniques Fused deposition modeling

    Instrument page
  • Ultra X6000 Laser CutterLaser cutter

    Modes: Adjustable power density; Autofocus with probe; Camera registration; Encoded positioning; Lateral and coaxial gas assist · Processes: 36" x 24" work area with vacuum boost

    Techniques Laser cutting

    Instrument page
  • VersaSTUDIO GS2-24 Vinyl CutterVinyl cutter

Metrology and testing 1

  • Oxford Instruments i04 Femto-IndenterNanoindentation system · Oxford Instruments Femto-Indenter i04

    Techniques Mechanical testing

    Instrument page

Processing and packaging 2

  • Kulicke and Soffa 4526 Wedge BonderWedge bonder

    Materials: Gold wire; Aluminum wire

    Techniques Wire bonding

    Instrument page
  • South Bay 560 Diamond SawDiamond wheel saw

    Techniques Diamond wheel cutting

    Instrument page

Scanning probe microscopy 5

  • Bruker MS-10 STMScanning tunneling microscope

    Resolution: Atomic resolution · Sample size: Sample sizes up to 10mm

    Techniques Scanning tunneling microscopy

    Instrument page
  • Bruker Multimode 8 AFMAtomic force microscope

    Modes: PeakForce Tapping, ScanAsyst, AC Tapping, Phase, Contact, Force Curves, LFM, MFM · Sample size: Sample sizes up to 10mm

    Techniques Atomic force microscopy · Conductive atomic force microscopy · Nanomechanical property mapping

    Instrument page
  • Cypher ESAtomic force microscope · Oxford Instruments Asylum Research Cypher

    Scanner: S and ES Scanners with 30um XY and 5um Z ranges · Resolution: Atomic resolution capabilities

    Techniques Atomic force microscopy · Conductive atomic force microscopy · Kelvin probe force microscopy

    Instrument page
  • Jupiter XRAtomic force microscope · Oxford Instruments Asylum Research Jupiter XR

    Scanner: Scanner with 100um XY and 12um Z ranges · Scan rates: > 10Hz

    Techniques Atomic force microscopy · Conductive atomic force microscopy · Kelvin probe force microscopy

    Instrument page
  • MFP-3D-BIO AFMAtomic force microscope · Oxford Instruments Asylum Research MFP-3D-BIO

    Scanner: Scanner with 90um XY and 40um Z ranges · Sample size: Sample sizes up to 50mm

    Techniques Atomic force microscopy · Fluorescence microscopy · Single-molecule force spectroscopy

    Instrument page

Thermal and transport measurement 4

  • Mellen High Temp FurnaceTube furnace

    Temperature range: to 1650C

    Techniques Thermal processing

    Instrument page
  • Muffle FurnaceMuffle box furnace

    Temperature range: up to 1000C

    Techniques Thermal processing

    Instrument page
  • Quartz Tube FurnacesQuartz tube furnace · Lindberg

    Temperature range: Temperature up to 1000C

    Techniques Thermal processing

    Instrument page
  • TAI SDT Q600Simultaneous DSC-TGA thermal analyzer · TA Instruments SDT Q600

    Atmosphere: Purge: N2, UHP N2, Air · Temperature range: Temperature range from ambient to 1500C

    Techniques Simultaneous differential scanning calorimetry and thermogravimetric analysis

    Instrument page
All techniques its instruments cover (19)
  • Conductive atomic force microscopy
  • Diamond wheel cutting
  • Energy-dispersive X-ray spectroscopy
  • Fluorescence microscopy
  • Fused deposition modeling
  • Kelvin probe force microscopy
  • Laser cutting
  • Mechanical testing
  • Multiphysics simulation
  • Nanomechanical property mapping
  • Polyjet 3D printing
  • Reactive ion etching
  • Scanning tunneling microscopy
  • Simultaneous differential scanning calorimetry and thermogravimetric analysis
  • Single-molecule force spectroscopy
  • Stereolithography
  • Thermal processing
  • Waterjet cutting
  • Wire bonding

Access & Collaboration

External access available

Rates
MPML staff may also provide service measurements on an as-needed basis.
Booking
External users may have access during daytime business hours (Mon-Fri: 8am to 6pm) when MPML staff are in the lab.
Approval
Users request access to the MPML core in BookitLab and access is typically approved in a day or two.
Services
Sample preparation, surface coating, 3D optical imaging, thermal characterization, optical characterization

Organization & Contact

Part of The University of Chicago

mrsec.uchicago.edu

Something wrong? Sign in to suggest a correction