Imaging Facility
Cornell Institute of Biotechnology page lists this facility with its advisory board members. The page does not describe its services.
Hubrief prepared this page from public sources. It doesn't mean the organization has joined or endorsed Hubrief.
Capabilities
X-ray computed tomography
CT imaging
As the source puts it: “CT”
Microscopy
Microscope imaging
As the source puts it: “Microscopes”
Ultrasound imaging
Ultrasound imaging
As the source puts it: “ultrasounds”
Instruments & Tools (17)
Clinical and preclinical imaging 2
Bruker Skyscan 1276 micro-CT
Micro-CT system
Research use: scan of live animals
Techniques X-ray computed tomography
Instrument pageVisualSonics Vevo-2100 Ultrasound
Ultrasound imaging system
Modes: contrast mode; Digital RF-mode (raw data output) · Resolution: 20-70 MHz
Techniques Contrast-enhanced ultrasound · Doppler flow measurement · Image-guided injection · Ultrasound imaging
Instrument page
Optical microscopy 12
Elyra Super Resolution Microscope (Zeiss)
Super-resolution microscope · Zeiss Elyra
Modes: SR-SIM, TIRF, PALM and STORM · Wavelengths: 405, 488, 561, and 640 nm laser lines
Techniques Photoactivated localization microscopy · Stochastic optical reconstruction microscopy · Structured illumination microscopy · Total internal reflection fluorescence microscopy
Instrument pageFluorescence microscope upright (Olympus)
Upright fluorescence microscope · Olympus BX-50
Modes: DIC, phase contrast, dark field, or polarization modes
Techniques Differential interference contrast microscopy · Fluorescence microscopy · Phase contrast microscopy
Instrument pageFVMPE-RS Twin Laser Multiphoton Microscope (Olympus)
Multiphoton microscope · Olympus FVMPE-RS
Wavelengths: 700-1300nm tuning range
Techniques Intravital imaging · Multiphoton microscopy
Instrument pageIVIS Spectrum
In vivo optical imaging system
Modes: 2D or 3D imaging modes · Filters: 10 excitation and 18 emission filters with spectral unmixing algorithms
Techniques Bioluminescence imaging · Fluorescence imaging · Optical and CT image co-registration · Spectral unmixing
Instrument pageKeyence BZ-X810 Microscope
Box microscope
Modes: Fluorescence, phase and transmitted light imaging modes · Objectives: Air immersion objective lenses (4-40X)
Techniques Fluorescence microscopy · Live-cell microscopy · Phase contrast microscopy · Transmitted light microscopy
Instrument pageLight sheet microscope (LifeCanvas Technologies SmartSPIM)
Light sheet microscope
Sample size: as large as a cm · Wavelengths: 488, 561, 640 and 785 nm fluorescence excitation lines
Techniques Cleared tissue imaging · Fluorescence microscopy · Light sheet microscopy
Instrument pageLSM710 Confocal (Zeiss)
Confocal laser scanning microscope · Zeiss LSM 710
Wavelengths: 405, 458, 488, 514, 561, and 633 nm laser lines
Techniques Confocal microscopy · Differential interference contrast microscopy · Live-cell microscopy
Instrument pageLSM880 Confocal upright - u880 (Zeiss)
Upright confocal microscope · Zeiss LSM880
Detectors: Spectrally-resolved detection with GaAsP sensitivity · Wavelengths: 405, 458, 488, 514, 561, and 633 nm confocal laser lines
Techniques Confocal microscopy · Fluorescence recovery after photobleaching
Instrument pageNikon CSU-W1 spinning disk confocal microscope
Spinning disk confocal microscope
Modes: Supports confocal and widefield imaging modes · Wavelengths: 405, 488, 561 and 640 nm laser lines with an additional NIR channel in widefield mode (708nm excitation)
Techniques Confocal microscopy · Live-cell microscopy · Widefield fluorescence microscopy
Instrument pageNikon Inverted Microscope
Inverted microscope · Nikon Eclipse Ti
Detectors: Andor Neo sCMOS camera · Objectives: Phase optics for 10x, 20x and 40x objectives; Oil immersion 60x objective
Techniques Fluorescence microscopy · Multi-position imaging · Phase contrast microscopy
Instrument pageSpinning Disk Confocal (Andor/Olympus)
Spinning disk confocal microscope
Frame rate: 50 frames/sec · Wavelengths: 405, 488, 561, and 640 nm laser lines
Techniques Live-cell microscopy · Multicolor fluorescence imaging · Spinning disk confocal microscopy
Instrument pageStereomicroscope (Zeiss)
Stereomicroscope
Techniques Differential interference contrast microscopy · Fluorescence microscopy · Phase contrast microscopy · Polarization microscopy · Stereomicroscopy
Instrument page
Other instruments 3
Hypoxia incubator
Vizgen Merscope
Xradia / Zeiss XRM-520 Versa nano-CT
Nano-CT system (X-ray microscope)
Resolution: 150nm and 50 microns · Sample size: specimens as large as 30cm in diameter
Techniques Micro-computed tomography · Nano-computed tomography
Instrument page
All techniques its instruments cover (32)
- Bioluminescence imaging
- Cleared tissue imaging
- Confocal microscopy
- Contrast-enhanced ultrasound
- Differential interference contrast microscopy
- Doppler flow measurement
- Fluorescence imaging
- Fluorescence microscopy
- Fluorescence recovery after photobleaching
- Hypoxia incubation
- Image-guided injection
- Intravital imaging
- Light sheet microscopy
- Live-cell microscopy
- Micro-computed tomography
- Multi-position imaging
- Multicolor fluorescence imaging
- Multiphoton microscopy
- Nano-computed tomography
- Optical and CT image co-registration
- Phase contrast microscopy
- Photoactivated localization microscopy
- Polarization microscopy
- Spatial transcriptomics
- Spectral unmixing
- Spinning disk confocal microscopy
- Stereomicroscopy
- Stochastic optical reconstruction microscopy
- Structured illumination microscopy
- Total internal reflection fluorescence microscopy
- Transmitted light microscopy
- Widefield fluorescence microscopy
Access & Collaboration
Access not stated
The official source doesn't say whether outside users can use it. Owning equipment doesn't mean it can be booked.