Instrument

FEI Helios NanoLab 600i DualBeam

Stanford Nano Shared Facilities

A DualBeam SEM/FIB combining a Ga+ focused ion beam and a high resolution field emission SEM column for milling, imaging, analysis and sample preparation at the nanoscale.

Official website Access not stated
From public sources · not yet confirmed by this organization · Checked Nov 19, 2026

Hubrief prepared this page from public sources. It doesn't mean the organization has joined or endorsed Hubrief.

Capabilities

  • Focused ion beam

    Milling with a focused Ga+ ion beam

    As the source puts it: “milling, imaging, analysis, and sample preparation down to the nanoscale”

  • Scanning electron microscopy

    High resolution field emission SEM imaging

    As the source puts it: “high resolution field emission scanning electron ("Elstar") column”

  • Energy-dispersive X-ray spectroscopy

    Elemental analysis with EDS detector

    As the source puts it: “EDAX TEAM EDS Enhanced Analysis System including Octane Plus detector”

  • Automated TEM sample preparation

    Automated TEM sample preparation with sectioning

    As the source puts it: “AutoTEM Automated TEM sample preparation with sectioning”

  • Gas injection deposition

    Tungsten, carbon and platinum deposition and etching gases

    As the source puts it: “Gas Injection Systems”

Instrument & Specifications

Kind Electron microscopy

Equipment model FEI Helios NanoLab 600i

Type
DualBeam SEM/FIB system
Manufacturer
FEI
Model
Helios NanoLab 600i
Configuration here
Omniprobe AutoProbe 200 in situ lift-out, EDAX TEAM EDS with Octane Plus detector, retractable STEM detector, gas injection systems, FIB charge neutralizer, plasma cleaner, FEI CryoCleaner

As Stanford Nano Shared Facilities states for its unit

Detectors
Elstar in-lens SE detector (TLD-SE), in-lens BSE detector (TLD-BSE), Everhart-Thornley SE detector (ETD), retractable STEM detector with BF/DF/HAADF segments
Spot size
4.0 nm at 30 kV using preferred statistical method
Resolution
0.8 nm at 30 kV (STEM)
Sample size
Maximum sample size: 150 mm diameter with full rotation
Accelerating voltage
0.35 – 30 kV

Access & Collaboration

Access not stated

Booking
Users must become qualified via nano@Stanford membership, Online SEM course, Helios Training Request Form; do not request training in NEMO
Sample requirements
Sample must withstand high vacuum without outgassing, be clean, electrically grounded; biological samples cannot exceed BioSafety Level 1

The official source doesn't say whether outside users can use it. Owning equipment doesn't mean it can be booked.